Introduction:
· Double-parameter meter, equipped with conductivity electrode and dissolved oxygen electrode, automatic identification of electrode by meter.
· Built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, automatic power-off and low voltage display.
· Automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: Europe and America series and China series.
· Adopt advanced conductivity measurement technology, use conductivity electrode of constant K=1, only need one-point calibration and meet the measurement precision requirement of 0.5μS/cm ~ 200 mS/cm.
· Ability to switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full scale.
· Conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
· Measurement mode of Dissolved oxygen has the function of automatic temperature compensation, automatic salinity compensation and manual air pressure compensation.
· New polarographic type dissolved oxygen electrode can measure temperature, salinity and dissolved oxygen simultaneously, equipped with special dissolved oxygen electrode calibration set, polarization only for 3~5 min.
· Meter meets IP57 rating, equipped with calibration solution and portable case.
Specification:
Category |
Product Name |
Basic features and specifications |
Conductivity |
Measuring range |
Conductivity:(0.00~19.99) μS/cm (20.0~199.9) μS/cm (200~1999) μS/cm (2.00~19.99) mS/cm (20.0~199.9) mS/cm TDS: (0 ~ 100) g/L Salinity: (0 ~ 100) ppt Resistivity:(0 ~ 100) MΩ·cm |
Resolution |
0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
|
Accuracy |
Meter: ±1.0% FS, Overall: ±1.5% FS |
|
Temp. compensation range |
(0 ~ 50) °C(manual) |
|
Electrode constant |
0.1 / 1 / 10 cm-1 |
|
Benchmark temperature |
25°C, 20°C and 18°C |
|
Dissolved Oxygen |
Measuring range |
(0 ~ 40.00) mg/L(ppm) (0 ~ 200.0) % |
Resolution |
0.1/0.01 mg/L(ppm) 1/0.1 % |
|
Accuracy |
Meter: ±0.10 mg/L, Overall: ±0.40 mg/L |
|
Response time |
≤30 s (25°C, 90%response) |
|
Residual current |
≤0.1 mg/L |
|
Temp. compensation range |
(0 ~ 45) °C(automatic) |
|
Salinity compensation range |
(0 ~ 45) ppt(automatic) |
|
Atmospheric pressure compensation range |
(66 ~ 200) kPa (manual) |
|
Automatic calibration |
Air saturated by water; water saturated by air |
|
Electrode type |
Polarogram type |
|
Other Technical Parameters |
Data storage |
200 groups |
Storage content |
Series number, measuring value measuring unit and temperature, |
|
Power |
Two AA batteries (1.5V x2) |
|
Size and weight |
meter:(65×120×31)mm/180g;Suitcase: (360×270×76) mm/1.6Kg |
|
Quality and safety certification |
ISO9001:2000, CE and CMC |
|
Working Condition |
Environment temperature |
5 ~ 35 °C(0.01grade) |
Environmental humidity |
≤85% |
|
IP rating |
IP57 Dustproof and waterproof |
Standard kits:
1. Model ELE-726 Conductivity/DO meter |
1set |
2. 2301T-S plastic conductivity electrode |
1pcs |
3. DO500 DO electrode |
1pcs |
4. 1413μS/cm conductivity standard solution (50mL) |
1btl |
5. DO503 membrane cap (DO electrode use) |
3pcs |
6. DO502 DO electrode inner solution (30mL) |
1pcs |
7. Cathode polishing paper |
1pcs |
8. Screw driver |
1pcs |
9. Spare AA batteries |
2pcs |
10. Operation manual |
1pcs |
11. Carrying case |
1unit |