Introduction
· Multi-parameter meter, equipped with pH electrode, ORP electrode and conductivity electrode, automatic identification of electrode by meter.
· Built-in microprocessor chips, intelligent functions such as automatic calibration, automatic temperature compensation, data storage, function set-up, self-diagnose information, automatic power-off and low voltage display.
· Automatic identification of 13 pH standard buffer solutions, three options of standard buffer solutions: Europe and America series, NIST series and China series.
· Able to set pH measurement modes of high purity water and pure water with ammonia.
· Automatic identification of 8 conductivity standard calibration solutions, two options of standard calibration solutions: Europe and America series and China series.
· Adopt advanced conductivity measurement technology, use conductivity electrode of constant K=1, only need one-point calibration and meet the measurement precision requirement of 0.5μS/cm ~ 200 mS/cm.
· Ability to switch among conductivity, TDS, salinity and resistivity. Multinomial calculation for TDS and salinity to ensure the conversion precision of the full scale.
· Conductivity measurement mode has the function of non-linear temperature compensation for high purity water.
· Meter meets IP57 rating, equipped with calibration solution and portable case.
Specifications
Category |
Product Name |
Basic features and specifications |
PH |
Measuring range |
(-2.00 ~ 19.99) pH |
Resolution |
0.1/0.01 pH |
|
Accuracy |
Meter: ±0.01pH; Overall: ±0.02pH |
|
Input current |
≤2×10-12 A |
|
Input impendence |
≥1×1012 Ω |
|
Stability |
±0.01 pH/3h |
|
Temp. compensation range |
(0 ~ 100) °C(automatic) |
|
ORP |
Measuring range (mV/ORP/EH) |
-1999mV ~ 0 ~ 1999mV |
Resolution |
1mV |
|
Accuracy |
Meter: ±0.1% FS, Overall: ±15mV |
|
Conductivity |
Measuring range |
Conductivity:(0.00~19.99) μS/cm (20.0~199.9) μS/cm (200~1999) μS/cm (2.00~19.99) mS/cm (20.0~199.9) mS/cm TDS: (0 ~ 100) g/L Salinity: (0 ~ 100) ppt Resistivity:(0 ~ 100) MΩ·cm |
Resolution |
0.01/0.1/1μS/cm 0.01/0.1 mS/cm |
|
Accuracy |
Meter: ± 1.0% FS, Overall: ±1.5% FS |
|
Temp. compensation range |
(0 ~ 50) °C(manual) |
|
Electrode constant |
0.1 / 1 / 10 cm-1 |
|
Benchmark temperature |
25°C, 20°C and 18°C |
|
Other Technical Parameters |
Data storage |
200 groups |
Storage content |
Series number, measuring value measuring unit and temperature, |
|
Power |
Two AA batteries (1.5V x2) |
|
Size and weight |
meter:(65×120×31)mm/180g;Suitcase: (360×270×76) mm/1.6Kg |
|
Quality and safety certification |
ISO9001:2000, CE and CMC |
|
Working Condition |
Environment temperature |
5 ~ 35 °C(0.01grade) |
Environmental humidity |
≤85% |
|
IP rating |
IP57 Dustproof and waterproof |
Standard Accessories
1. Model ELE-731 pH/ORP/Conductivity meter |
1set |
2. 201T-S plastic pH/ATC three-in-one combined electrode |
1pcs |
3. 301Pt-S plastic ORP combined electrode |
1pcs |
4. 2301T-S plastic conductivity electrode |
1pc |
5. pH standard buffer solution (pH4.00, pH7.00 and pH10.01/50mL) |
1btl/each |
6. 1413μS/cm conductivity standard solution (50mL) |
1bottle |
7. Screw driver |
1pcs |
8. Spare AA batteries |
2pcs |
9. Operation manual |
1pcs |
10. Carrying case |
1unit |