Product Description
Suitable for film plastic film, high barrier materials, solar energy back, sheet, composite materials, aluminized, co-extruded film, etc, foil, sheet materials and plastics, rubber, paper, glass, metal and other material film, bottles, bags, cans, boxes and other packaging container oxygen transmission rate test.
Features
1. Coulometric method principle, pressure balance on both sides of sample , which is closer to the sample production or practical usage;
2. Imported micro moisture electrolysis sensors, flow control and sensor;
3. Patented pipe washing technology ,accelerate the test speed, higher test efficiency;
4. Professional pipe cleaning system to ensure the cleanliness of the carrier gas, improve test accuracy;
5. Special specimen mounting technology to enhance sample sealed;
6. Patented fogless humidifier, precisely adjust the test gas humidity;
7. Pure semiconductor cold and hot bidirectional temperature control technology, it can heat or cool at will, high precision control, safe systems, high reliability, can test in a variety of temperature conditions;
8. Save when power-off;
9. Monitor in whole process, automatically record, sampling rate could be adjustable; automatically repeat tests;
10. The test process can reproduce in whole process; powerful graphics curve function, easy to test comparatively and analyze;
11. Automatically test: set test parameters, the test automatically carry on after starting, and automatically judge when test end and save the test results;
12. There is a universal database system in host software; data can be exported, could store the data, query, print, and so on. Through the analysis of historical data, it’s easy to grasp the historical dynamic condition of product.
13.Could extend to test vessel.
Standards Compliant
GB/T 19789、ASTM D3985、ASTM F2622、ASTM F1307、ASTM F1927、ISO 15105-2、JIS K7126-B、YBB 00082003
Technical index:
Description |
Parameter |
Measuring Range |
Film: 0.01 ~ 30,000 cc / m2 · day Container: 0.001 ~ 150cc / pkg · day (optional) |
Testing precision |
Film: 0.01 cc / m2 · day Container: 0.001 cc / pkg · day |
Number of Sample |
1 |
Number of Main sensor |
1 |
Test Mode |
Data independence |
Sample Area |
50cm2, round |
Sample Thickness |
≤3mm |
Display and Control mode |
Computer Control |
Temperature Range |
10 ℃ -55 ℃ |
Temperature Accuracy |
± 0.1 ℃ |
Humidity Range |
5 ~ 95% RH |
Humidity Accuracy |
± 1% RH |
Test Pressure |
-0.1MPa ~ + 0.1MPa |
Air Pressure |
0.2 MPa ~ 0.8 MPa |
Test Gas |
Oxygen (O2) |
Carrier Gas port |
¢1/8” |
Correction Mode |
Baseline correction, standard gas calibration standard film calibration |
Host Size |
585 × 640 × 380mm (L × B × H) |
Weight |
42Kg |
Power |
220V AC 50HZ |
Standard configuration:
No. |
Description |
Quantity |
Model |
Unit |
Comments |
1 |
Test Host |
1 |
OPT-E-11H |
Set |
Include: vacuum sensor systems, pressure sensors, gas circuit control systems, environmental control systems, communication systems, display and control systems. |
2 |
Oxygen Trap |
1 |
Agilent |
pc |
|
3 |
Professional Testing Software |
1 |
OPT series |
set |
1 Operating System Requirements: Windows 7 above; 2 Hardware Requirements: Memory 1G, 80G hard drive or more. |
4 |
Vacuum Pipe |
2 |
Length 1.5m, diameter 1/8 |
pc |
|
5 |
Communication Cable |
1 |
|
pc |
Standard RS232 communication cable, length 2m |
6 |
Air Valve |
2 |
|
pc |
|
7 |
Circle Sample Cutter |
1 |
|
set |
50cm2 sampler, cut the sample |
8 |
sealing grease |
1 |
Dow Corning |
pc |
|
9 |
USB Conversion Line |
1 |
|
pc |
USB1.1 extension cable, length 1m. |
10 |
Test Computer |
1 |
|
set |
Dell or Lenovo |
Optional:
Container test fixtures and accessories, container temperature and humidity control device
Test gas bottles (oxygen, etc.)