Introduction:
· The most widely used pH + Conductivity Double-Parameter measurement meter.
· Meter meets with the requirement of international GLP standards. Its features up to automatic calibration, automatic temperature compensation, data storage, timing measurement, clock display, RS-232 output, function setting and self-diagnose etc.
· There are three different measurement modes: stable display mode; time measurement mode; continuous measurement mode.
· Automatically recognize pH buffer solution. User can choose anyone from three series of standard buffer solutions: Europe & USA series, NIST series and China series.
· Adopt advanced and original conductivity measurement technology, use 1 pc of conductivity electrode (K=1), it can meet measuring accuracy requirement for range within 0.5μS/cm ~ 200mS/cm by using only one-point calibration.
· Can switch Conductivity, TDS, Salinity and Resistivity.
· Meter has the only product serial number.
· Dustproof and waterproof meter meets IP54 standards. All sockets are seal protected by the silica gel caps.
Specifications:
pH |
Measuring range Resolution Accuracy Input current Input impendence Stability Temp. compensation range |
(-1.99 ~ 19.99) pH 0.1/0.01/0.001 pH Meter: ±0.01 pH, connect meter with electrode: ±0.01pH ≤1×10-12 A ≥3×1012 Ω ±0.01 pH/3h (0 to 100) °C (automatic or manual) |
mV |
Measuring range(mV/ORP/EH) Resolution Accuracy |
-1999.9mV ~ 0 ~ 1999.9mV 0.1mV ±0.03% FS |
Conductivity |
Measuring range
Resolution Accuracy Temp. compensation range Electrode constant Reference temperature |
Conductivity:(0.00~20.00) μS/cm (20.0~200.0) μS/cm (200~2000) μS/cm (2.00~20.00) mS/cm (20.0~200.0) mS/cm Resistivity:(0 ~ 100) MΩ·cm TDS: (0 ~ 100) g/L Salinity: (0 ~ 100) ppt 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm Meter: ±1.0% FS, connect meter with electrode: ±1.5% FS (0 ~ 50) °C (automatic) 0.1 / 0.5 / 1 / 5 / 10 / 50 / 100? cm-1 25°C, 20°C and 18°C |
Temperature |
Measuring range Resolution Accuracy |
-10°C~ 110°C 0.1°C 5~ 60°Crange: ±0.4°C other range: ±0.8°C |
Other Technical Parameters: |
Data storage Storage content
Power Communication connector Size and weight Quality and safety certification |
300 groups Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time DC9V/300mA RS232 160 × 190 × 70mm/880g ISO9001:2008, CE and CMC |
Working Condition |
Environment temperature Environmental humidity IP rating |
5 ~ 35 °C(0.01grade) 15 ~ 30 °C(0.001grade) ≤75% IP54 Dustproof and waterproof |
Standard kits:
1. Model ELE-521 Lab pH/Conductivity meter |
1set |
2. Model 602 flexible electrode holder |
1pc |
3. 201T-M plastic pH/ATC three-in-one combination electrode |
1pc |
4. 2301T-M plastic pH/ATC three-in-one combination electrode |
1pc |
5. pH standard buffer solution (pH4.00, pH7.00 and pH10.01/50mL) |
1btl/each |
6. 1413μS/cm conductivity standard solution(50mL) |
2btls |
7. 9V power adapter (meter use) |
1pc |
8. RS-232 communication cable |
1pc |
9. ELE-521 communication software disk |
1pc |
10. Operation manual |
1unit |
11. Brief operation instruction |
1unit |
12. Packing List |
1pc |