Welcome: U-THERM INTERNATIONAL (H.K.) LIMITED

   Home   |   Product   |   Intelligent Laser Particle Size Analyzer

Particle Size Analyzers

  • Intelligent Laser Particle Size Analyzer
Intelligent Laser Particle Size Analyzer

Intelligent Laser Particle Size Analyzer

  • Model: PSA2005
  • Product description: Intelligent Laser Particle Size Analyzer
  • INQUIRY

Overview:

Intelligent full automatic laser diffraction particle size analyzer with principle of Mie Scattering to precisely determine the particle size distribution from 0. μm1 to 1000μm. It enables you understand materials well, such as abrasives, adhesives, agrochemical, barite, Batteries, Bentonite, Boron Carbide, Brucite, Bubble, Calcite, Calcium Carbonate, Carbon Black, Catalysts, Cement, Ceramics, Chemicals, Clay, Coal, Coatings, Corundum, Cosmetics, Diamond Powder, Dolomite, Diatomite, Emulsion, Environmental, Explosives, Ferrite, Flour, Fluorescent, Fluorite, Food & Beverage, Food Additive, Graphite, Grinding, Inks, Kaolin, Medicine, Metal Powder, Mica, Milling, Minerals, Oxides, Paints, Paper, Petrochemical, Pharmaceuticals, Pigments, Plaster, Plastics, Polymers, Quartz, Refractory, Resins, Silica, slurry, Soil Sediments, Starch, Sulfur, Synthetics, Talc, Toners, Tourmaline, Wollastonite, Zeolite, Zirconium Silicate etc. Industry.

Main Specifications:

Model Name

PSA2005A

PSA2005B

Standard

ISO13320-1:1999GB/T19077.1-2008Q/0100JWN001-2013

Principle

MIE Scattering Principle

Size range

0.01μm-1000μm

0.1μm-1000μm

Photodetectos

90 pcs

69 pcs

Accuracy error

<1% (Deviation of D50 on national standard sample)

Repeatability error

<1% (Deviation of D50 on national standard sample)

Laser

High performance He-Ne Laser λ= 632.8nm, p>2mW

Service time>25000 hour

Wet dispersion

Ultrasonic

Frequency:40KHz   Power:35W, Time: ≥1S

Agitator

Revolutions Speed: 0-3000RPM (Adjustable)

Circulation

Rated Flow:8L/min    Rated Power:10W

Sample tank

Volume: 350mL

Operation mode

Manual and Full automatic

Optical alignment system

Full automatic optical path alignment system

Software function

Analysis mode

Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.

Statistic Method

Volume Distribution, Quantity Distribution

Statistic Comparison

Several Testing Results of samples

Different batches of samples testing result,

Samples before and after processing,

Test result of samples in different time.

User-defined Analysis

Figure out percentage according to the particle size

Figure out particle size according to the percentage

Figure out percentage according to the particle size range

Meet demands of representation of particle test in different industries

Test Report

Word, Excel, Photo (Bmp), Text etc.

Multiple-language Support

Multiple language Support

Intelligent operation

Automatically control water inflow, dispersion, test and analysis. Better Repeatability after remove human-factor

Testing speed

<2min/time (including all the procedures) fastest measuring time<10S

Running temperature

15 -35

Outer dimension

L85cm*W39cm*H45cm

Net weight

40Kg

Main Features:

1, Advanced design of light path:

A patented technique of Fourier transforms of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument, and ring shaped of multi-element silicon photo-diode ensure gathering all the light signals of particles, highly improve the resolution.

2, Built-in intelligent liquid dispersion units:

We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, the sample will be sufficiently dispersed.

3, Unconstrained free fitting analysis patent techniques:

The particle analysis software uses a unique unconstrained data fitting analysis patent technique that we developed to obtain data of real particle size distribution; this is particularly important for researchers.

4, Modern measurement control:(Intelligent SOP Operation)

Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.

6, User-friendly Operation:

manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.

7, Three-dimension automatic light path alignment system:

A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment, precision is up to 0.1um, this releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.

8, Quick measurements:

set “automatic” mode, all operation procedures are performed automatically, automatic water supply, automatic ultrasonic sample, stirring, circulation, background testing, sample testing, analysis, draining and cleaning, which significantly reduces the time for measurements, the full process < 2 minutes.

9, Data analysis:

Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard.


Ⅱ test analysis view

After testing, if necessary, to select records generated an average result, the system analyzes the formation of the recording. When the automatic mode test, without data processing, forming and maintaining a comprehensive system automatically analyzed test records.

Scheme: