Instruments Features:
l Rapid analysis: in one minute more than 21 to 26 elements can be scanned (domestic only this one).
l Wavelength error of indication and repeatability: Wavelength error of indication: ± 0.02nm
l Repeatability: ≤ 0.003nm
l High precision: relative standard deviation RSD ≤ 1.0%.
l Stability: the relative standard deviation RSD ≤ 1.5.0%.
l Measurement Range: from trace to common.
l Low detection limit: ppb (ug / L) level (some elements of the detection limit see Appendix 1).
l Multi-element analysis: 70 metal elements and some non-metallic elements (such as B, P, Si, Se, Te) can be quantitative or qualitative analysis.
l Measurement Methods: single-element and multi-element order measurement.
l Power: adjustable 800W-1200W.
Specifications
RF generator (RF)
l HK-8100 similar instrument ICP spectrometer, automatic ignition, automatic control, etc.
l Circuit type: self-inductance feedback oscillation circuit, the output of coaxial cable, matching tuning, feedback signals from power, closed-loop control.
l Frequency: 40.68 MHz ± 0.05%
l Frequency stability: ≤ 0.1%
l Output power :800-1200 W
l Output power stability: ≤ 0.1%
l Leakage of electromagnetic field strength of radio: 20 cm from the device.
Electric field strength E: <2 V / m
l Torch tube: three concentric type, diameter 20 mm quartz tube torch.
l coaxial-type sprayer 6 mm diameter.
l double-room fog diameter 34 mm.
l Argon carrier gas flow meter specifications and pressure gauges Specifications:
n 1 plasma gas flow meter (100-1000) L / h (1.6-16L/min).
n 2 auxiliary gas flow meter (10-100) L / h (0.16-1.66L/min)
n 3 Carrier gas flow meter (10-100) L / h (0.16-1.66L/min)
n 4 carrier gas regulator valve (0-0.4Mpa) L / h
n 5 cooling water temperature :21-26 ℃ flow> 5 L / min pressure> 0.1 Mpa cooling water: resistivity > 1 Ω
n focal length: 1000mm.
n grating Specifications: plasma etching holographic grating; groove density of 3600 lines / mm, engraved lines of:
80 × 110mm (optional groove density of 2,400 lines / mm, engraved lines of: 80 × 110mm).
n dispersion of the penultimate line: 0.26nm
n 1/(Line Dispersion rate): 0.26nm.
n resolving power: ≤ 0.008 nm
n scan wavelength range:
n 3600 lines / mm scan wavelength range :180-500 nm
n 2400 lines / mm scan wavelength range :180-800 nm
n stepper motor drive the smallest step: 0.0005nm.
n Radio and the incident slit: 20 μ m
n mirror specifications: (78 × 105 × 16) mm
n temperature keeping: 38 ℃ ± 1 ℃.
n photomultiplier specifications: R212UH or R928
n photomultiplier negative high-voltage :0-1000 V stability of <0.03%
n photomultiplier current measurement range: 10-4~10-9A
n signal acquisition for the V / F exchange: 1mV corresponding 100 Hz
n sampling circuit uses foreign high-precision operational amplifiers, improve the accuracy of the sensitivity of the equipment and greatly.
n data acquisition equipment communicates with computer through the serial port connection, thus simplifying the circuit to connect more convenient.
n Metering mode, single, multi-element sequential measurement
Output of computers and equipment
Host, monitor, printer configuration: according to user requirements.
A: ICP-AES spectrometer standard configuration is as follows
Product Name |
Model |
Units |
Quantity |
Remarks |
Plasma Spectrometer single-channel scanning |
ICP-HK-8100 |
piece |
1 |
Host |
Intelligent temperature cooling water cycle |
YT-1800 |
piece |
1 |
accessory |
Computer Host |
Lenovo or HP business machines |
piece |
1 |
accessory |
Monitor |
Lenovo or HP business machines |
piece |
1 |
accessory |
printer |
HP laser printer |
piece |
1 |
accessory |
Sampling System |
Quartz torch tube fog room, atomizer |
set |
2 |
accessory |
Exhaust system |
Axial fan |
Set |
1 |
accessory |
Instructions |
Text and the electronic version |
Set |
1 |
accessory |
Packing List |
Chinese and English |
Copy |
1 |
accessory |
n Wavelength error of indication and repeatability: Wavelength error of indication: ± 0.02nm Repeatability: ≤ 0.003nm
n Scan wavelength range :180-500 nm/3600 lines / mm, 180nm-800 nm/2400 line / mm
n Measuring resolution: ≤0.008 nm
n Instrument repetitive: the relative standard deviation RSD ≤ 1.0%
n The stability of equipment: the relative standard deviation RSD ≤ 1.5%
n Typical elements of the detection threshold: μ g / L (Appendix 1)
Appendix 1 (see table below for some elements of the detection units ppb or ug / L)
Element |
Be |
Mg |
Ca |
Sr |
Ba |
Sc |
Y |
Eu |
Yb |
Wavelength nm |
313.042 |
279.553 |
393.366 |
407.771 |
455.403 |
335.373 |
371.030 |
381.967 |
369.419 |
The detection limit |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
<1.0 |
Element |
Lu |
La |
Gd |
Dy |
Ho |
Er |
Tm |
Zn |
Cd |
Wavelength nm |
261.542 |
333.749 |
342.247 |
353.170 |
345.600 |
337.271 |
313.126 |
213.856 |
226.502 |
The detection limit |
<1.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
Element |
Fe |
Ti |
Cu |
Mn |
V |
B |
Ni |
Cr |
Co |
Wavelength nm |
239.562 |
344.941 |
324.754 |
257.610 |
309.311 |
249.773 |
221.647 |
205.552 |
238.204 |
The detection limit |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<3.0 |
<5.0 |
<5.0 |
<5.0 |
<5.0 |
element |
Zr |
Mo |
Ag |
Au |
Si |
Al |
Ir |
P |
Hg |
Wavelength nm |
343.823 |
202.030 |
328.068 |
242.795 |
251.611 |
396.152 |
224.268 |
213.618 |
194.227 |
The detection limit |
<5.0 |
<5.0 |
<5.0 |
<5.0 |
<5.0 |
<10.0 |
<10.0 |
<10.0 |
<10.0 |