Welcome: U-THERM INTERNATIONAL (H.K.) LIMITED

   Home   |   Product   |   Distillation Tester (low temperature Double units)

Distillation Tester

  • Distillation Tester (low temperature Double units)
Distillation Tester (low temperature Double units)

Distillation Tester (low temperature Double units)

  • Model: PT-SYD-6536B
  • Power supply: AC (220±10%) V, 50Hz
  • Heating power: 1000W×2
  • Receiving cylinder: 100ml, division value is 1ml
  • Product description: Distillation Tester (low temperature Double units)
  • INQUIRY

Summary:

The instrument is designed and made as per standards GB/T6536 Test Method for Distillation Characteristics of Petroleum Products and ASTM D86 Standard Test Method of Distillation for Petroleum Products at Atmospheric Pressure. It is suitable to determine the distillation characteristics of gasoline, aviation gasoline, jet fuels, solvent having special boiling point, naphtha, diesel oil, distillate fuels, and other petroleum products.

 This instrument is a kind of double-units instrument which the minimum temperature of the condenser pipe can reach 0℃.It is an ideal distillation tester for petroleum products under low temperature condition.

 

I. Main technical features

1.The instrument adopts low temperature and double units working mode. The minimum temperature can set to 0℃.It can do test for one sample or two samples at same time. It highly improves the work efficiency.

2.It adopts digital temperature controller, stainless-steel heater, new type refrigeration compressor and electric stirrer to constitute constant temperature bath. The temperature in the bath is uniform, can fully meet the requirements of test.

3.It adopts special designed structure; cooling speed is fast. The bath temperature can cool down from room temperature to 0℃ within 50 minutes.

4.It adopts special heating furnace to ensure the safety of test. Heating power can be continuously adjusted to meet the requirements of test.

 

II. Main technical specifications

1.Power supply:  AC (220±10%) V, 50Hz

2.Heating power: 1000W×2.

3.Receiving cylinder: 100ml, division value is 1ml.

4.Distillation flask: 125ml, meet the requirements of GB/T 6536 and ASTM D86

5.Thermometer:(-2~300)℃ and (-2~400)℃. Division value 1℃.

6.Flask support board: SiC, bore diameter is: φ32mm, φ38mm, φ50mm.

7.Temperature controller:

1) Range:  0℃60℃   2) Accuracy:  ±0.5℃    3) Display:  LED

Note: The temperature control is to control the temperature of condensate in the condenser pipe.

8.Ambient temperature:  ≤30℃

9.Relative humidity:  ≤85%

10.Cooling system: New type refrigeration compressor

11.Maximum power consumption:  4000W

12.Dimension: 730mm×530mm×580mm

 

Ⅲ. Accessories

PT-SYD-6536B Distillation Apparatus Accessories and Documents List 

No.

Name

Unit

Qty

Memo

1

PT-SYD-6536B Distillation Apparatus

Set

1

 

2

Distillation flask (125 ml)

Piece

2

 

3

Thermometer (2300).(2400), scale division is 1

Piece

Each 2

 

4

Glass container (Φ100mm×240mm)

Piece

2

 

5

Silica gel stopper (3#)

Piece

4

 

6

Silica gel stopper (4#)

Piece

4

 

7

Silicon carbide board, pore size Φ32mm.Φ38mm.Φ50mm

Piece

Each 2

 

8

Graduated flask (100 ml)

Piece

2

 

9

Iron block

Piece

2

 

10

Test platform (pad under the test vessel)

Piece

2

 

11

Fuse 15A (Ф5×20)

Piece

4

 

12

Fuse 10A (Ф5×20)

Piece

2

 

13

Stopping ring for thermometer (1 #)

Piece

8

 

14

Observation window glass

Piece

2

 

15

Condensate pipe outlet cover

Piece

2

 

16

Pull rope

Piece

1

 

17

Operation Manual

Piece

1

 

18

Quality Certificate

Piece

1

 

19

Repair Guarantee

Piece

1

PT-SYD-6536B Distillation Apparatus's Reagent and Auxiliary Equipment

No 

Name 

Specification 

Quantity 

Memo 

1

Petroleum ether60-90 

Analytical pure 500ml

2 bottles

 

2

Glycol

500ml

6 bottles

Condensation medium under 0~20 

3

Distilled water

2.5L

1 bottle

 

4

Zeolite

500g

1 bottle

 


Notes

1.The reagent and equipment for installing the instrument are supplied by end-users themselves.
2.The usage, management and saving of poisonous and harmful reagent, pls operate according to the relative principle.
3.PLS read the operation manual and industry standard before using the instrument. 