Product advantages
A high-precision temperature control instrument formed by combining microcomputer processing and PID control, suitable for the concentration or preparation of large batches of samples;
By blowing nitrogen into the surface of the heated sample, the solvent in the sample is quickly evaporated and separated, thereby achieving the purpose of anaerobic concentration of the sample and keeping the sample purer; using a nitrogen blower instead of a commonly used rotary evaporator for concentration can simultaneously concentrate Multiple samples save time and efficiency.
Features
1. LED dual display screen, easy to operate, convenient for monitoring temperature and time;
2. The height of the air chamber can be adjusted, and the standard air needle length is 85mm;
3. When concentrating toxic solvents, the entire system can be placed in a fume hood;
4. Built-in over-temperature protection device, safe and stable;
5. Each air needle flow regulating valve corresponds vertically to the module hole position, making the adjustment intuitive and convenient. The blow pipes are independent of each other and will not cause cross-contamination.
Application
1. Pharmaceutical drug testing: such as traditional Chinese medicine pharmaceuticals and drug screening
2. Food and beverages: such as milk, wine, beer, etc.
3. Pesticide residue analysis: such as vegetables, fruits, grains, plant tissues
4. Environmental analysis: such as drinking water, groundwater and polluted water samples
5. Biological analysis: such as hormone analysis, sample preparation in liquid phase, gas phase and mass spectrometry analysis
Optional modules
Model |
Test tube diameter |
Number of test tubes |
Hole depth |
59070103 |
10mm |
12 |
47mm |
59070104 |
12mm |
12 |
47mm |
59070105 |
13mm |
12 |
47mm |
59070106 |
15mm |
12 |
47mm |
59070107 |
16mm |
12 |
47mm |
59070108 |
19mm |
12 |
47mm |
59070109 |
20mm |
12 |
47mm |
Specification
Model |
TSC12 |
TSC24 |
TSC96 |
Temperature control range |
Room temperature +5~150℃ |
Room temperature +5~150℃ |
Room temperature +5~150℃ |
Temperature setting range |
25~150℃ |
25~150℃ |
25~150℃ |
Temperature stability@25~90℃ |
±0.3C |
±0.3C |
±0.3C |
Temperature stability@90~150℃ |
±0.6℃ |
±0.6℃ |
±0.6℃ |
Module temperature uniformity@37℃ |
±0.2℃ |
±0.2℃ |
±0.2℃ |
Temperature display accuracy |
0.1°C |
0.1°C |
0.1°C |
Timing range |
0min~99h59min |
0min~99h59min |
0min~99h59min |
Maximum lift stroke of air needle plate |
205mm |
205mm |
205mm |
Gas joint outer diameter |
Φ10 |
Φ10 |
Φ10 |
Nitrogen pressure |
≤ 0.1MPa |
≤ 0.1MPa |
≤ 0.1MPa |
Nitrogen flow |
0-10L/min |
0-10L/min |
0-10L/min |
Air needle length |
85mm |
85mm |
85mm |
Sample throughput |
1 standard 12-hole module |
2 standard 12-hole modules |
1 standard 96-holel modules |
Input power |
AC220V/AC110V,50/60Hz |
AC220V/AC110V,50/60Hz |
AC220V/AC110V,50/60Hz |
Power |
200W |
400W |
400W |
Fuse |
250V,3A/6A,φ5*20 |
250V,3A/6A,φ5*20 |
250V,3A/6A,φ5*20 |
Dimensions |
290×210×400mm |
290×210×400mm |
290×210×400mm |
Net weight |
6KG |
6KG |
6KG |