Summary
The instrument is designed and made as per national standard of People’s Republic of China GB/T511 and ASTM D4807 Standard Test Method for Mechanical Impurity of Petroleum Products and Additive (Weight Method). It is used to determine mechanical impurity in hydrocarbons, heavy oils, lubricating oils, and additives.
I. Main technical features
1. This instrument is composed of glass vessels, water bath, funnel, suction pump, motor and digital temperature controller. It has features such as small size, light weight, rapid heating rate and easy installation.
2. The temperature control funnel is small and light. It can save operation time and solvent.
3. Desktop structure. Simple design. Easy to use.
II. Main technical specifications
1. Power supply: AC 220V±10%, 50 Hz
2. Heating power for water bath:1000 W
3. Temperature control range for water bath:Room temperature~90 ℃, adjustable
4. Bath temperature display:Digitally displayed by LED
5. Temperature control accuracy for water bath:±1 ℃
6. Temperature control range for funnel:Room temperature~90 ℃, adjustable
7. Funnel temperature display:Digitally displayed by LED
8. Temperature control accuracy for funnel:±2 ℃
9. Size: (1) Control case:390 mm× 260 mm× 590 mm
(2) Water bath:390 mm× 290 mm× 370 mm
10. Ambient temperature:≤35 ℃
11. Relative humidity:≤85%
12. Maximum power consumption:1200 W
PT-SYD-511B Mechanical Impurity Tester Accessories and Documents List
No. |
Name |
Unit |
Qty |
Memo |
1 |
Water bath box (content cup bracket) |
Set |
1 |
|
2 |
Controlling box |
Set |
1 |
|
3 |
Temperature controlling funnel |
Set |
1 |
|
4 |
Temperature sensor |
Piece |
1 |
|
5 |
Suction bottles (1000 ml, including white stopper of 16#) |
Set |
2 |
|
6 |
Glass funnel (Ф90) |
Piece |
2 |
|
7 |
Support rod, locking member |
Set |
2 |
|
8 |
Funnel holder |
Piece |
1 |
|
9 |
Mercury thermometer 0 ℃~ 100 ℃, scale division 0.5 ℃
|
Piece |
1 |
|
10 |
Measuring glass(1000ml) |
Piece |
2 |
|
11 |
Power lead wire |
Piece |
1 |
|
12 |
Silica gel plug (1#) |
Piece |
2 |
|
13 |
Stopping ring for thermometer (1#) |
Piece |
4 |
|
14 |
Fuse 10A(Ф5×20) |
Piece |
2 |
|
15 |
Rubber tube (outside diameter Ф12) |
Meter |
1.5 |
Used for filtering |
16 |
Rubber tube (outside diameter Ф12) |
Meter |
2 |
Used as an exhaust |
17 |
Operation Manual |
Piece |
1 |
|
18 |
Temperature control device usage manual |
Piece |
1 |
|
19 |
Quality Certificate |
Piece |
1 |
|
20 |
Repair Guarantee |
Piece |
1 |
|
PT-SYD-511B Mechanical Impurity Tester's Reagent and Auxiliary Equipment
No. |
Name |
Specification |
Quantity |
Memo |
1 |
Absolute ethyl alcohol |
Analytical pure 500ml |
3 bottles |
|
2 |
Diethyl ether |
Analytical pure 500ml |
3 bottles |
|
3 |
Methylbenzene |
Analytical pure 500ml |
3 bottles |
|
4 |
Distilled water |
3 grades |
1.5 litres |
|
5 |
Quantitative filter paper |
Intermediate speed, Φ125mm |
1 box |
|
6 |
Ten thousandth-Balance |
Range 200g |
1 set |
|
7 |
Weighing bottle |
Medium-sized |
1 piece |
|
8 |
Beaker |
1000ml |
1 piece |
|
9 |
Glass rod |
|
1 piece |
|
10 |
Glass drying vessel |
240mm or 300mm |
1 piece |
|
11 |
Electrothermal blowing dry box |
|
1 piece |
105°C drying the weighing bottle with filter paper |
Notes:
1、The reagent and equipment for installing the instrument are supplied by end-users themselves.
2、The usage, management and saving of poisonous and harmful reagent, pls operate according to the relative principle.
3、PLS read the operation manual and industry standard before using the instrument.