Welcome: U-THERM INTERNATIONAL (H.K.) LIMITED

   Home   |   Product   |   Autoclavable Pipette (Adjustable and Fixed Volume)

Mechanical Pipette

  • Autoclavable Pipette (Adjustable and Fixed Volume)
Autoclavable Pipette (Adjustable and Fixed Volume)

Autoclavable Pipette (Adjustable and Fixed Volume)

  • Fully autoclavable
  • Lightweight
  • Digital display clearly reads volume setting
  • The pipettes cover volume range of 0.1μl to 10ml
  • Product description: Autoclavable Pipette (Adjustable and Fixed Volume)
  • INQUIRY

All pipettes have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.

 

Fully autoclavable
The MicroPette plus pipettes can be fully autoclaved and withstood steam sterilizes at 121℃, 1 atm for 20 minutes. The pipettes can be autoclaved without special preparations. After autoclaving the pipette must be cooled down and left to dry over 12 hours.
It is recommended to check the performance of the pipette after each autoclaving. It is also recommended to grease the piston and seal of the pipette after each 10 autoclaving.

 

Features for MicroPette plus
- Fully autoclavable
- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Manufactured from innovative material
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate

Features for multi-channel MicroPette plus
- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips

 

Ordering Information

MicroPette Plus Single-channel Adjustable Volume Pipettes

Cat No.

Volume Range

Increment

Test Volume

Maximum permissible systematic error (Inaccuracy)

Maximum permissible random error (Imprecision)

%

μl

%

μl

PP713111010000

0.1-2.5μl

0.05μl

2.5

2.50%

0.0625

2.00%

0.05

1.25

3.00%

0.0375

3.00%

0.0375

0.25

12.00%

0.03

6.00%

0.015

PP713111040000

0.5-10μl

0.1μl

10

1.00%

0.1

0.80%

0.08

5

1.50%

0.075

1.50%

0.075

1

2.50%

0.025

1.50%

0.015

PP713111050000

2-20μl

0.5μl

20

0.90%

0.18

0.40%

0.08

10

1.20%

0.12

1.00%

0.1

2

3.00%

0.06

2.00%

0.04

PP713111060000

5-50μl

0.5μl

50

0.60%

0.3

0.30%

0.15

25

0.90%

0.225

0.60%

0.15

5

2.00%

0.1

2.00%

0.1

PP713111080000

10-100μl

1μl

100

0.80%

0.8

0.15%

0.15

50

1.00%

0.5

0.40%

0.2

10

3.00%

0.3

1.50%

0.15

PP713111090000

20-200μl

1μl

200

0.60%

1.2

0.15%

0.3

100

0.80%

0.8

0.30%

0.3

20

3.00%

0.6

1.00%

0.2

PP713111110000

50-200μl

1μl

200

0.60%

1.2

0.15%

0.3

100

0.80%

0.8

0.30%

0.3

50

1.00%

0.5

0.40%

0.2

PP713111140000

100-1000μl

5μl

1000

0.60%

6

0.20%

2

500

0.70%

3.5

0.25%

1.25

100

2.00%

2

0.70%

0.7

PP713111160000

200-1000μl

5μl

1000

0.60%

6

0.20%

2

500

0.70%

3.5

0.25%

1.25

200

0.90%

1.8

0.30%

0.6

PP713111170000

1000-5000μl

50μl

5000

0.50%

25

0.15%

7.5

2500

0.60%

15

0.30%

7.5

1000

0.70%

7

0.30%

3

PREVIOUS:Mechanical Pipettes (Adjustable and Fixed Volume) NEXT:Electronic Pipette