Purpose:

The instrument is designed and made as per the national standard of People’s Republic of China GB/T1841 and ASTM D2170 Standard Test Method for Viscosity of Polyolefin Resin Solution. It is used to determine the viscosity of decahydronaphthalene solution of polythene and polypropylene at the stipulated temperature. The instrument can also be used to determine the viscosity of asphalt at the stipulated temperature as per the industrial standard of People’s Republic of China T0619 Asphalt Kinematic Viscosity Test (Capillary Viscometer Method).

 

I. Main technical features

1.High precision digital temperature controller. Electric stirring motor.

2.High temperature resistant glass bath. Double layer structure.

3.Desktop structure. All-in-one design.

4.The maximum heating temperature is 135℃ (or 180℃).

 

II. Main technical specifications

1. Power supply: AC 220 V±10%, 50 Hz

2. Heating power: 1700 W

3. Temperature range: Ambient to 135.0℃ (or 180℃).

4. Temperature control accuracy: ±0.1℃

5. Mercury-in-glass thermometer: Scale division 0.1℃.

Range 100℃~150℃ (for maximum 135.0℃)

Range 100℃~150℃ and range 150℃~200℃ (for maximum 180.0℃)

6. Bath capacity: about 23 L

7. Sample quantity: You can make determination using 3 capillary viscometers at a time.

8. Stirring motor (1) Power: 6W (2) Speed: 1200 RPM

9. Ambient temperature: -10℃+35℃

10. Relative humidity: 85

11. Temperature sensor: RTD, Pt100

12. Maximum power consumption: 1800 W

13. Capillary viscometer: One group of Cannon-Fenske Opaque capillary viscometers; 7 pieces in total. They are N0.200, 300, 350, 450, 500 and 600 (The inner diameters of R tube of them are 1.02, 1.26, 1.48, 1.88, 2.20, 3.10 and 4.00 mm respectively).

14. Overall dimension:    530mm×400mm×670mm (Bath is included)

 

PT-SYD-265E Kinematic Viscometer Accessories and Documents List 

No.

Name

Unit

Qty

Memo

1

PT-SYD-265E Kinematic Viscometer

(Including glass inside and outside cylinder, stirring device, rubber ring etc.0)

Set

1

High temperature 135

2

Capillary viscometer Pinkevitch Viscometer, Cannon-Fenske Routine Viscometer, Standard Ubbelohde Viscometer)

Group

 

1

Capillary viscometer characteristics, specification, quantity according to business agreement

3

Mercury thermometer (100~150, scale division is 0.1)

Piece

1

 

4

Weight ball

Piece

1

 

5

Sensor

Piece

1

 

6

Bakelite cover

Piece

4

 

7

Stopping ring for thermometer (1#)

Piece

2

 

8

Capillary viscometer holder

Piece

4

 

9

Silica gel stopper (3#)

Piece

2

 

10

Fuse 10A(Ф6×30)

Piece

4

 

11

Round glass

Piece

1

 

12

Wire control timer (Plug in when using by clients)

Piece

1

 

13

Washing ear ball

Piece

1

 

14

Operation manual

Piece

1

 

15

Temperature control device usage manual

Piece

1

 

16

Quality certificate

Piece

1

 

17

Product warranty card

Piece

1

 


PT-SYD-265E Kinematic Viscometer's Reagent and Auxiliary Equipment

No. 

Name 

Specification 

Quantity 

Memo 

1

Glycerol or silicone oil

Open flash point 215 

20L

When test temperature above 180,using silicone oil

2

Petroleum solution

1L

1L/bucket

Trichloro ethylene, gasoline, kerosene, choose one only 

3

Distilled water

Three grades

1 litre

 

4

Washing ear ball

 

1 piece

 


Notes
1. The reagent and equipment for installing the instrument are supplied by end-users themselves.
2. The usage, management and saving of poisonous and harmful reagent, pls operate according to the relative principle.
3. PLS read the operation manual and industry standard before using the instrument. 